TH-X1000 (not for SoftCore)
Tungsten-halogen Lamp
Standard Lamphead for all Rifa eX models except EX 44
Lamp/Beam Data
Lamp Code Volts Watts °K Avg Life FC (lux)5' FC (lux)10'
For Rifa eX 55 – Maximum 500w
EHC 120 500 3200 300 hr 72 (778) 19 (209)
EHD 120 500 3000 2000 hr 69 (745) 18 (198)
JCV 220V-500WBM 220 500 3000 2000 hr 78 (846) 21 (228)
JCV 240V-500WBM 240 500 3000 2000 hr 66 (710) 17 (188)
For Rifa eX 66 – Maximum 750w (May also use lamps for LC-55)
EHF 120 750 3200 300 hr 109 (1180) 30 (326)
EHG 120 750 3000 2000 hr 89 (962) 24 (262)
FKR/240 240 650 3200 300 hr 92 (990) 25 (270)
For Rifa eX 88 – Maximum 1000w (May also use lamps for LC-66)
FEL 120 1000 3200 300 hr 195 (2110) 56 (608)
FEP / 220 240 1000 3200 150 hr 178 (1920) 53 (567)
FEP / 240 240 1000 3200 150 hr 160 (1730) 45 (491)
If you use the fluorescent accessory heads, you will find that you can’t pack up the Rifa eX with them
installed. Recommended practice is to store the Rifa eX with its supplied lamphead installed.
It is not necessary to remove the supplied standard head when storing or shipping the light.
When storing the accessory lampheads, use the supplied protective cap to cover the lamphead
connection pins. Store screw-threaded fluorescent lamps in Lamptubes.
If you use your Rifa eX with its standard supplied lamphead, you would still set up & strike in the
normal manner. The supplied head for the Rifa eX models 55, 66 & 88 is the TH-X1000.
The supplied head for the Rifa eX 44 is (the lower max. wattage) TH-X300. The TH-X300 head will fit
the 55, 66 & 88 Rifa eX’s, but the TH-X1000 will not fit the Rifa eX 44. See the below charts for more
information. Neither TH-X1000 nor TH-X300 heads will fit the Lowel SoftCore.
See reverse side for info on fluorescent lampheads to use with Rifa eX & SoftCore.
n
Both Rifa eX and SoftCore fixtures use the same mounting
system and share screw-threaded fluorescent lampheads,
however Rifa eX has 2 tungsten-halogen lampheads which
cannot be used by SoftCore.
n To remove head, make sure fixture is on a stand,
unplugged, and lamphead, if installed, is cool to touch.
n For FLO-X1, FLO-X3 or FLO-X5 heads, install & remove
lamphead without their lamps installed.
n To remove lamphead, push & twist until fixture base pins
line up with cutouts in lamphead, then carefully remove head.
n To install lamphead, line up larger & smaller J-hook
cutouts on head with larger & smaller pins on fixture base.
n With lamphead securely in place, carefully install lamp(s).
Grasp fluorescent lamps by base to remove or install.
n See images below for further information. Example shown
is Rifa eX, but same techniques apply for SoftCore.
Lowel eXchange System Lamphead Instructions
Carefully remove lamphead. Push in and twist lamphead, locking light fixture base side pins
to J-hook cutout. Install flo lamps carefully by holding lamp base.
Orient replacement head J-hook cutouts with correct pins
(1 larger, 1 smaller).
The Lowel eXchange System Lampheads are professional lighting instruments. Read these instructions plus Rifa
eX & SoftCore instructions fully, as well as lamp manufacturer’s warnings, before operating. If you need Rifa eX or
SoftCore instructions, visit the Instructions downloads section of www.lowel.com
TH-X300 (not for SoftCore)
Tungsten-halogen Lamp
Standard lamphead for Rifa eX 44. Fits all Rifa eX models.
Lamp/Beam Data
Lamp Code Volts Watts °K Avg Life FC (lux) 5' FC (lux) 10'
JCV14.5-50WC 12/14 50 3200 100 hr 7 (80) 2 (22)
GCC 12 100 3200 100 hr 8 (81) 2 (22)
GCB 30 200 3200 100 hr 20 (220) 5 (58)
FSH 120 125 3200 100 hr 15 (166) 4 (46)
FVM 120 105 3200 250 hr 14 (148) 4 (40)
FVL** 120 200 3200 200 hr 33 (356) 9 (100)
GCA 120 250 3200 100 hr 39 (418) 10 (111)
CP/96 120 300 3400 75 hr 49 (532) 14 (147)
GLF/P44 230 235 3200 100 hr 35 (381) 9 (102)
CP/97 230 300 3200 75 hr 54 (582) 15 (159)
** Longer life lamp recommendation (slightly lower wattage).
These readings taken with Rifa 44 eX. For readings from other
Rifa eX models, visit www.lowel.com
&
The modular / interchangable lampheads of the Lowel eXchange System offer versatil-
ity to Rifa eX and SoftCore users. Larger models of Rifa eX can use lower wattage &
lower voltage tungsten halogen lamps, or screw-threaded daylight fluorescent lamps.
SoftCore users can select the right screw-threaded fluorescent lamphead & lamp to
match the size of their softbox and output needs.
Notes for Rifa eX Users
Exchanging Heads on Rifa eX & SoftCore
For :
Vue de la page 0
1 2

Résumé du contenu

Page 1

TH-X1000 (not for SoftCore)Tungsten-halogen LampStandard Lamphead for all Rifa eX models except EX 44Lamp/Beam DataLamp Code Volts Watts °K Avg Life F

Page 2

Lamp/Beam DataLamp Code Volts Watts °K Avg Life FC(lux) 5' FC(lux) 10'For Rifa eX 44 – Maximum 300wE1-27 120 27 5500 8000 hr 10 (108) 3 (30

Commentaires sur ces manuels

Pas de commentaire